High Quality Defi Xpress Portable Defibrillator Monitor Biphasic and AED, Built-in Printer

Original price was: $3,445.00.Current price is: $2,795.00.

FREE SHIPPING! Delivery in 3 Days

Xpress is a defibrillator Monitor with voice alarm which can meet your clinical needs from Basic Life Support (BLS) to Advanced Cardiac Life Support (ACLS).

  ... people are viewing this right now

Defibrillators benefit patients who experience a sudden case of heartbeat is arrhythmias. In these instances
Defibrillators are an important tool for anyone in the vicinity of a victim suffering from ventricular arrhythmia as well. arrhythmia renders the patient unconscious. the heart may beat too fast, too slow or an irregular mix of both. The anticipated outcome of sucharrhythmias is either cardiac arrest or a stroke.




Display
Screen Type: High-resolution display
Screen Size: 7 inches (17.7 cm) diagonally
Sweep Speed: 25mm/sec
Information: Heart Rate .  Lead/Pads.  Alarm .  On/Off  . SpO2 .  AED
Functions and Prompts Alarm Selection and Limits Delivered Energy.
Defibrillator
Waveform: Biphasic (BTE)
Charge Time: Less than 7 seconds with a new fully charged battery.
Energy Display: Monitor display indicates both selected and delivered energy.
Charge Prompt Type: Voice and visual prompts.
Electrode Impedance Measurement Range: 0-250 ohms.
ECG Monitoring
Patient Connection: 3-lead ECG cable or 5-lead ECG cable paddles.
Lead Selection: Displayed on monitor paddles I II III AVR AVL AVF V.
ECG Size: 0.25 0.5 1 1.5 2 4 cm/mV display on monitor.
Heart Rate: 20-300BPM.
Heart Rate Alarm: On/Off displayed on monitor user-selectable.
Smart Alarms: Beeper/voice prompts indicate shock able rhythm.
Battery
Type: Rechargeable Ni-MH battery 12V.
Operating time: For a new fully charged battery: 60 defibrillator discharges at maximum energy or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions.
SpO2 Module (Options):
Measurement Range: 30~100% ±2% between 80%~90% others ±5%
Alarm Range: User set high limit and low limit.
Alarm Accuracy: ±10% within setting values.
Alarm time Accuracy: less than 12 sec.
1-Meditech Pulse Oximeter
2-Nellcor Pulse Oximeter
EtCO2 Module (Options):

CO2 Range 0 to 13%(0-98.8mmHg@BTPS)
CO2 Accuracy <5.0% CO2 (at BTPS) ± 3 mmHg
                         >5.0% CO2 (at BTPS) < 10% of reading
Breath Rate 3~60 BPM
Measurement Accuracy ±1BPM 
Pacemaker (Options):

Type: VVI
Pulse Type: rectangular,constant current
Pulse Amplitude: 0 to 180 mA ± 10% or 5 mA (whichever is greater).
Pacing Rate: Variable from 30 ppm to 180 ppm ±1.5% (increments or decrements by a value of 2 ppm)
Multi-Function Electrode: (MFE) Pads: multipurpose defibrillation/pacing electrodes
Pause: Pacing pulse frequency reduced by a factor of 4 when activated
Refractory Period: NC(VVI demand do not have this specification)
Pulse Width: (20+ 1.5 ms)
Output Protection: Fully defibrillator protected and isolated

Recorder

Paper: 50mm thermal.
Speed: 12.5mm/sec 25mm/sec 50mm/sec. User-selectable 6-second delay.
Printing Method: High-resolution thermal print head.
Print-out Modes: Manual or automatic user-configurable.
On/Off Control: Front panel and paddle.
Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge.
 AED Mode
 AED Function: Auto analyze and charge x3 with programmable auto energy level selection screen prompts and voice prompts.
 Shockable Rhythms: Ventricular fibrillation with amplitude >=200uV ventricular tachycardia with rates >=140bpm and QRS complex wave duration >=140ms.
 Charge Control: Control on device front panel press key on paddle.
 Prompts: Voice and visual prompts.
 Manual Mode
 Energy Selection: Selectable at 2 5 7 10 20 30 50 70 100 150 200 300 360 joules.
 Synchronized Mode: Synchronizes defibrillator pulse to patient’s
 R-wave. “SYNC” message displayed on monitor.

SpO2 Module (Options):

 

The Specification of physical electronic isolation defibrillator battery electromagnetic compatibility and rhythm recognition performance will be described in this section:
Data Acquisition and Analysis
The Defi® Xpress is no longer automatically configured to a certain frequency response. There are two diagnostic frequency options: 0.05-150 Hz
Diagnostic Frequency Filter and 0.05-40 Hz Filtered Diagnostic
Frequency filter. See chapters 7 on switching between these two options.
Defibrillator
Waveform Details:
The tables below provide details of the waveforms delivered by the Defi® Xpress when connected to resistive loads of 25 50 and 100 Ohms and set to its maximum output.
The waveforms are characterized by DEFI XPRESS values ​​for peak current (Ip) for biphasic: duration of The first output phase (tphase1) and duration of the second output phase (tphase2).
The values ​​shown are within 10%.
Waveform: Truncated Exponential Biphasic
Output Energy Accuracy:
+/- 10% or 1J (whichever is greater) at 50 ohms
+/- 15% or 1J (whichever is greater) at 25 to 100 ohms
Energy Select:
External: 2 5 7 10 20 30 50 70 100 150 200 300 360 J.
Charge Time:
< 06 seconds @ 200 J (with a Ni-MH 12 volt – MEDITECH battery ).
< 12 seconds @ 360 J (with a Ni-MH 12 volt – MEDITECH battery after15discharges).
< 15 seconds @ 360 J (no battery 90% AC mains voltage)
Charge Indicator: Audible and graphic.
Output :
Adult paddles pediatric adapter and multipurpose hands-free adapter available.
Synchronizer: Delivers energy within 60 msec.
Disarm: Front panel switch.
Monitor/Display
Input:
3-lead 5-lead patient cable
Size: 7 inches (16.5 cm) diagonal non-fade.
Type: color (TFT)
Display Resolution: 800 x 600 pixels.
Sweep Speed: 12.5mm/s25mm/s50mm/s
Lead Selections: I II III AVR AVL AVF V.
Frequency Response: (User-selectable).
0.7 to 20 Hz operation mode
0.3 to 40 Hz Monitoring mode
0.05 to 150 Hz Analysis mode
0.5 to 30 Hz AED mode
Common Mode Rejection:>=60dB
Heart Rate Meter: 20 to 300 BPM.
Heart Rate Alarms: User-selectable.
Size: 0.125 0.25 0.5 1 2 4 cm/mv and auto-ranging.
ECG Output: 1 V/mV.
Heart Rate Response to Irregular Rhythm: (AAMI EC13-1992 section 4.1.2.1.e.)
Alarms
Heart Rate Spo2 Alarm:
Audible: 5 pulse 800 tone with a PW of 150 msec a PRI of 225 msec and a repetition interval of 10 seconds.
Visual: Heart Rate Alarm causes the displayed heart rate to flash at 2 Hz. This display is located at the top of the display and is 0.4″ high and 0.28 to 0.840″ wide depending on num-ber of digits in the heart rate. Is amber black white or whatever the color the display text is.
Lead Fault Alarm:
Audible: 3 pulse 500 Hz triplet tone with a PW of 200 msec a PRI of 310 msec. When the HR alarm is set or the pacer is on the lead fault tone repeats at a repetition interval of 20 seconds.
Visual: Lead Fault condition causes a “LEAD FAULT” message to be displayed on the trace along with a dashed line the width of the trace. The text is 0.18″ high and is the color of the display text. The dashed line is 5″ Long the width of the display. The signal is not modulated.
Physiological Alarms (Spo2):
Audible: See Heart Rate Alarm
Visual: Physiological alarms cause the displayed parameter to flash at 2 Hz. Color is amber white or the same as the display colored text.
Mute Duration: 90 seconds.

End-tidal CO2 (EtCO2):

Safety ETCO2:BF type
Power Requirements 12.0V±0.2V DC
Power Consumption 100mA (typical with pump on)  200mA (extreme status)
Operating Temperature Range 5~50℃
Shipping/Storage Temperature Range -20~+70℃
Relative Humidity 0-85% (non-condensing)
Dimensions 96×91×36mm
CO2 Range 0 to 13%(0-98.8mmHg@BTPS)
CO2 Accuracy <5.0% CO2 (at BTPS) ± 3 mmHg
                         >5.0% CO2 (at BTPS) < 10% of reading
Breath Rate 3~60 BPM
Measurement Accuracy ±1BPM
Warm-up Time 10 seconds
Response Time Detector: 10mS,
System: Dependent Upon Implementation, Pneumatics
and Water Separation Technique
Flow Control 50~250ml/min
Interface Highly configurable serial digital interface (TTL/RS232)
Automatic Offset Calibration Time and temperature based, as well as on-demand
Pacemaker

Type: VVI
Pulse Type: rectangular,constant current
Pulse Amplitude: 0 to 180 mA ± 10% or 5 mA (whichever is greater).
Pacing Rate: Variable from 30 ppm to 180 ppm ±1.5% (increments or decrements by a value of 2 ppm)
Multi-Function Electrode: (MFE) Pads: multipurpose defibrillation/pacing electrodes
Pause: Pacing pulse frequency reduced by a factor of 4 when activated
Refractory Period: NC(VVI demand do not have this specification)
Pulse Width: (20+ 1.5 ms)
Output Protection: Fully defibrillator protected and isolated

Recorder

Type: High-resolution thermal array.
Annotation: Time date ECG lead ECG gain heart rate defibrillation and treatment summary ACLS events.
Paper Width: 50 mm.
Paper Speed: 25 mm/sec 50 mm/sec 12 Lead 50 mm/sec
Delay: 6 seconds.
Frequency Response:
Automatically set to monitor’s frequency response.
Battery
High Capacity Type: Ni-MH 12V volt – MEDITECH
Up to 4 hours ECG monitoring or 110 full-energy dis-charges or 3 hours combined ECG Spo2 and monitor-ing
Proper battery care is required to maintain maximum avail-able capacity.
Low Battery Indicator:
Flashing low battery icon on display and flashing LED on front panel..
Recharge Rate: 80% in 7.5 hours. 100% in 9 hours.
General
Weight: 10 pounds (4.95 kg) (basic configuration).
Size: 13 x 12.5 x 5.3 inches (33 x 31.8 x 13.5 cm).
Operating:
Temperature*: 0 to 45° C
Humidity* (NC): 15 to 95% RH (30 to 90% with CO2 probe)
Vibration*: MIL-STD 810E
Shock / Drop*: MIL-STD 810E
Altitude: Up to 4572 M (15000 feet)
Transport and Storage:
Temperature: -30 to 70°C (-20 to 70°C with CO2 probe)
Humidity: 15 to 95% RH (non-condensing)
Atmospheric pressure: 860 to 1060 hPa
Shock/vibration: ISTA 1A
Enclosure Protection*:
Solid Foreign object: IEC 529 IP2X
Water: IEC 529 IPX4.
All tests performed per AAMI DF-2 Defibrillation Standard.
Operating Power:
Ni-MH 12 volt – MEDITECH
SAED Rhythm Recognition Performance
The DEFI XPRESS SAED algorithm exceeds the requirements of ANSI/AAMI
Standard:
ECG Cable (5 Leads) …… 1Pcs
AED Pad Adapter  ……….. 1Pcs
AED Pad  ……………………..1pcs
Ground Cable   ……………. 1Pcs
Power Cable  ………………. 1Pcs
Thermal Paper Role …….. 1Pcs
Cleaning Cloth  ……………. 1Pcs

Options:

AED Pad for Child
ECG Cable (3 Leads)
ECG Alligator Clips (Metal)
SpO2 Cable (Adult hard shell sensor)
SpO2 Cable (Adult Soft shell sensor)
SpO2 Cable (Neonatal soft sensor)

SpO2 Cable (Pediatric hard shell sensor)
SpO2 Cable (Pediatric Soft shell sensor)
SpO2 Cable (Child finger clip)
SpO2 Cable (multi-site Y type)
SpO2 External Cable

NIBP Cuff (infant 8 – 14 cm 5/Bag)

NIBP Cuff (Child 13 – 20 cm 5/Bag)
NIBP Cuff (Small Adult 18 – 26 cm 5/Bag)
NIBP Cuff (Adult 26 – 35 cm 5/Bag)
NIBP Cuff (Adult Long 29 – 38 cm 5/Bag)
NIBP Cuff (Large Adult 32 – 42 cm 5/Bag)
NIBP Cuff (Large Adult Long 35 – 44 cm 5/Bag)
NIBP Cuff (Thigh 42 – 50 cm)
NIBP Tube 150cm
Paper Role
Defibrillator Wall mounts (3 Models)
Defibrillator Trolley (5 Models)
Defibrillator Case
EtCO2 Module

IrDA USB Adapter for ECG Data transfer

CD Software  for ECG Data transfer

My Cart
Wishlist
Recently Viewed
Compare Products (0 Products)
Compare Product
Compare Product
Compare Product
Compare Product
Categories