BJ8103 Canulate drill(System 8000)
$2,457.00
– High speed canulate drill for intramedullary interlocking nail surgery
– Autoclavable design with imported motor for low noise operation
– Warranty for 2 years for long service life
– Connects to various flexible reamers for convenience during surgery
Description
BJ8103 Cannulate Drill (System 8000)
High-speed cannulate drill designed for intramedullary interlocking nail and arthroscopic surgery. Features an imported motor for low-noise operation, full autoclavability, and compatibility with flexible reamers for seamless intraoperative transitions. Engineered for precision, durability, and 2-year warranty coverage.
Range / sizes: Compatible with standard cannulate drill bits and K-wires; flexible reamer compatibility
Sterilisation: 135°C autoclavable at 1.6 MPa (Improved type ≤155°C); handpiece only
Low Noise ≤40dB
2-Year Warranty
Clinical overview
The BJ8103 Cannulate Drill is a precision-engineered power tool specifically designed for intramedullary interlocking nail surgery and arthroscopic procedures. With ergonomic design and imported motor technology, it delivers consistent high-speed performance while maintaining low operational noise (≤40 dB), reducing surgeon and OR fatigue. The handpiece is fully autoclavable at 135°C (improved models to 155°C), enabling efficient sterilization protocols without compromising motor integrity.
The system’s modular design allows rapid connection and disconnection of various flexible reamers during surgery, streamlining workflow and reducing operative time. Powered by environment-friendly nickel-metal hydride batteries with dedicated charging infrastructure, the BJ8103 provides reliable cordless operation with extended service life backed by comprehensive 2-year warranty coverage on the handpiece.
Key features & surgeon benefits
Versatile surgical applications
- Holds K-wires and standard cannulate drill bits
- Compatible with multiple flexible reamers for intraoperative changes
- Suitable for intramedullary nailing, arthroscopic, and trauma procedures
Optimized OR efficiency
- Quick-change reamer interface reduces setup and transition time
- Low-noise operation (≤40 dB) minimizes OR disruption
- Cordless design with aseptic battery transfer ring for seamless handoffs
Long-term value
- 2-year handpiece warranty; 3-month battery and consumables coverage
- Eco-friendly nickel-metal hydride battery technology
- Durable medical-grade stainless steel construction
Tailored specifications
- Speed range: 0–460 rpm (standard) or 0–600 rpm (customized)
- Sterilization: 135°C standard or up to 155°C (improved type)
- OEM configurations and specialized reamer attachments available
Technical specifications
| Indications | Intramedullary interlocking nail surgery, arthroscopic procedures, K-wire placement |
|---|---|
| Sizes / range | Compatible with standard cannulate drill bits and K-wires; flexible reamer compatibility |
| Material | Medical-grade stainless steel handpiece; imported motor; nickel-metal hydride battery |
| Sterilisation | 135°C autoclavable at 1.6 MPa (Improved type ≤155°C); handpiece only — battery not autoclavable |
| Packaging | Handpiece, battery, charger, aseptic battery transfer ring, operating manual, warranty card |
| Warranty | 2 years on handpiece; 3 months on battery and consumable items |
Technical performance
| Output power | 20 W |
|---|---|
| Speed (rpm) | 0–460 (default) / 0–600 (customized) |
| Torque | 1 Nm |
| Operating voltage | 7.2 V |
| Noise level | ≤40 dB |
Standard instrument composition
| Item | Description | Qty |
|---|---|---|
| Handpiece | BJ8103 Cannulate drill with ergonomic design | 1 |
| Battery | Nickel-metal hydride rechargeable battery (7.2 V) | 1 |
| Charger | AC/DC charging unit | 1 |
| Aseptic battery transfer ring | Sterile interface for intraoperative battery exchange | 1 |
| Operating manual | Instruction and maintenance guide | 1 |
| Warranty card | 2-year coverage documentation | 1 |
Important clinical notes
- Sterilization limits: Do not exceed 135°C (or 155°C for improved models); higher temperatures will damage the motor.
- Battery management: Remove battery from handpiece immediately after surgery to prevent automatic discharge and extend battery life. Battery is not autoclavable.
- Reamer care: Wash flexible reamers immediately after surgery with purger to prevent blood adhesion; allow to dry completely before sterilization.
- Handpiece maintenance: Ensure no water enters the battery compartment after sterilization.
- Reamer durability: Flexible reamer blades (medical stainless steel) are designed for single-use per procedure to prevent breakage and maintain precision.
- Speed considerations: Cannulate drills operate at ~600 rpm for nail/K-wire applications, compared to standard bone drills (~300 rpm) and acetabulum reamers with higher torque.
Get in touch for pricing & availability
Contact our sales team to request a detailed quote, discuss customization options, or arrange a product demonstration. We provide comprehensive technical support and clinical guidance for all System 8000 instruments.
Email: info@tedsmedical.com
- ankle surgery
- Biphasic Defibrillator
- Cordless Drill
- dental surgery
- drill for veterinary surgeon
- ECG
- ECG analysis
- ECG machine
- ECG monitor
- External Fixator
- foot surgery
- Hand Foot Surgery
- Joint Operation
- Maxillofacial surgery
- medical drill
- medical saw
- monophasic defibrillator
- Neurosurgery
- ortholimited
- orthopedic bone drill
- orthopedic drill
- orthopedic power tools
- orthopedic saw
- Patient Monitor Touch screen
- pneumatic drill
- pneumatic power tools
- portable defibrillator
- pulse lavage
- Pulse Oximeter
- surgical bone saw
- surgical pneumatic drill system
- surgical pulsed lavage
- titanium vet plates
- Trauma Operation
- Ultrasound Scanner
- Veterinary Bone Saw
- Veterinary Device
- veterinary drill
- Veterinary ECG
- veterinary implants
- Veterinary Orthopedic Drill
- vet surgery
- visible
- Vital Sign Monitor
- wound irrigation
- + Show more
Related Products
– Model NO.: NS-1011
– Type: Medical Electric Saw / Medical Saw
– Material: Stainless Steel
– Feature: Reusable
– Medical Device Regulatory Type: Type 2
– Color: Black/Silver
– Weight: 1700g
– Suitable for all brands of intramedullary nail and kirschner wire operations
– Center hole diameter is 4.0mm for precise concentricity
– Input voltage range of 110V-240V/50Hz
– Output power of ≤120W
– Battery capacity of 1800mA/h
– Rated speed of 0-1000rpm with customization available
– Sterilization process using HTHP at 134-138°C
– Powerful acetabullar reaming drill for grinding bone tissue
– Compatible with any brand acetabular grinder and medullary cavity reamer
– Features a diameter of drill chuck of 0-8mm
– Operates on input voltage of 110V-240V/50Hz
– Output power of ≤120W for efficient performance
– Built-in 2500mA/h battery capacity for extended use
– Customizable rated speed of 0-400rpm for versatile applications
– Suitable for various orthopaedic joint surgeries
– Rapid and accurate bone tissue cutting
– Smooth and tidy bone edges with low temperature rise
– Multiple saw blade sizes available for clinical needs
– Autoclavable bone drill for trauma surgery
– High power output of ≥30w and speed of 0-1100 r.p.m
– Low noise operation with long service life
– Standard configuration includes handpiece, battery, charger, chuck, and more
– Suitable for various ankles’ orthopaedic joint surgery
– Quick and accurate bone tissue cutting
– Low temperature rise during operation
– Comes with a variety of saw blade sizes
– Intended for small bone surgeries like hand, foot, and ankle operations
– Popular in the USA and European countries
– Spectacular feedback from users in these regions
– Mainly used in grinding bone tissue
– Compatible with any brand acetabular grinder and medullary cavity reamer
– Adjustable diameter of drill chuck from 0-8mm
– Input voltage range of 110V-240V/50Hz
– Output power of ≤120W
– Battery capacity of 1800mA/h
– Rated speed range of 0-400rpm (customizable)
– Versatile bone drill suitable for orthopedic trauma surgery
– Features a drill chuck diameter of 0-8mm
– Operates on an input voltage of 110V-240V/50Hz
– Output power of ≤120W for efficient drilling
– Battery capacity of 1800A/h for reliable performance
– Rated speed of 0-1200rpm with customization available
– Sterilization using HTHP method at 134-138°C
– Bojin System 2000 is a veterinary multifunctional surgical power tool designed for working with large bone fragments
– Features a range of attachments for various surgical applications such as sagittal saw, bone drill, and TPLO saw
– Hand block with electric drive, high speed (up to 15,000 rpm), and NiMh battery for efficient performance
– Components made of durable medical stainless steel, sterilizable by autoclaving for convenience and safety
– Veterinary TPLO Saw with 2 batteries, ideal for animal surgery
– Features 130W output power and a speed range of 0-16000rpm
– Can be sterilized up to 135ºC, ensuring optimal hygiene
– Made of hard oxidized aluminum alloy for durability
– Step-less speed regulation and ergonomic design for operator safety
– Includes Ni-MH batteries and various accessories for convenience
– Optional saw blades available in 8 sizes for versatile use
– Ergonomic design for comfortable use
– Autoclavable for easy sterilization
– Features a top quality brushless motor for efficiency
– Comes with a variety of saw blade sizes for versatility
– Ergonomically designed sagittal saw for cutting bone during joint surgery
– Autoclavable and low noise motor for steady and quick cutting
– Comes with a variety of blade lengths and thickness options
– 2-year warranty on the handpiece and 3 months on fast consumption items











